NH-YJV Fire-Resistant Low-Voltage Copper Core Cable
Category:
Product Description
Description of use
XLPE insulated power cables not only have excellent electrical properties, mechanical properties, heat aging resistance, environmental stress resistance and chemical corrosion resistance, but also have a simple structure, easy to use, and are not limited by the laying drop. With the advantages of high long-term working temperature (90 degrees) and large transmission capacity, XLPE insulated power cable products include a full range of flame-retardant and non-flame-retardant XLPE insulated power cables.
Execution Standard
The performance of XLPE insulated (flame retardant) power cables conforms to the national standard GB/T12706.1-2008, equivalent to IEC60502-2004, and the flame retardancy conforms to the national standard GB/T19666-2005.
Scope of application
★ System: This product is suitable for transmission of electric energy in power lines with AC 50Hz, rated voltage 0.6/1KV (the highest voltage of the system is 1.2KV).
★ Occasions: Laying in metallurgy, electric power, construction and other industries indoors, cable trenches, pipelines, direct-buried and fixed-purpose occasions that cannot withstand mechanical external forces.
Using properties
★ Rated voltage: AC rated voltage of power frequency is 0.6/1KV, and the maximum voltage of AC system should not exceed 1.2KV.
★ Working temperature: The maximum allowable long-term working temperature of the cable conductor is 90°C. When short-circuited, the maximum temperature of the cable conductor is 250°C, and the duration does not exceed 5s.
★ Ambient temperature: The minimum ambient temperature for cable operation is -10°C.
★ Laying temperature: When installing and laying, the temperature should not be lower than 0℃.
★ Bending radius: Minimum bending is recommended, the bending radius of single-core cables shall not exceed 20D, and the bending radius of multi-core cables shall not exceed 15D.
Model and name
| Model | Name | When to use | |
| Copper core | Aluminum core | ||
| YJV ZR-YJV |
YJLV ZR-YJLV |
XLPE insulated PVC sheathed (flame retardant) power cable | Where it is laid in indoor or outdoor tunnels, cable trenches, or buried in loose soil, it can withstand a certain amount of laying traction, but cannot withstand external mechanical forces. Single-core cables are not allowed to be laid in magnetic in pipeline |
| WDZ-YJY | WDZ-YJLY | XLPE insulated low-smoke halogen-free sheathed power cable | |
| YJV22 ZR-YJV22 |
YJLV22 ZR-YJLV22 |
XLPE insulated steel tape armored PVC sheathed (flame retardant) power cable | It is laid outdoors and is also used for buried laying. It can be subjected to mechanical external force, but it cannot withstand large pulling force |
| YJV62 ZR-YJV62 |
YJLV62 ZR-YJLV62 |
XLPE insulated non-magnetic metal tape armored PVC sheathed (flame retardant) power cable | |
| WDZ-YJY23 | WDZ-YJLY23 | XLPE insulated steel tape armored low-smoke halogen-free sheathed power cable | |
| YJV32 ZR-YJV32 |
YJLV32 ZR-YJLV32 |
XLPE insulated thin steel wire armored PVC sheathed (flame retardant) power cable | Laying in shaft water or areas with high drop, it can withstand mechanical external force and considerable pulling force |
| YJV72 ZR-YJV72 |
YJLV72 ZR-YJLV72 |
XLPE insulated non-magnetic wire armored PVC sheathed (flame retardant) power cable | |
| WDZ-YJY33 | WDZ-YJLY33 | XLPE insulated thin steel wire armored low-smoke halogen-free sheathed power cable | |
| YJV42 ZR-YJV42 |
YJLV42 ZR-YJLV42 |
XLPE insulated thick steel wire armored PVC sheathed (flame retardant) power cable | Laying in vertical shafts, seabeds or areas with high drop, the cables can withstand large positive pressure and tension |
| WDZ-YJY43 | WDZ-YJLY43 | XLPE insulated thick steel wire armored low-smoke halogen-free sheathed power cable | |
Structure Diagram